Standard Features

Benefits

Dual compressor / Dual circuit chillers

Reliability; 75% of design capacity available if one compressor down

Redundant CHW & CW pumps

Reliability; ease of maintenance

Variable Primary Flow design

Energy efficiency; optimized to load; lower first cost

Integrated component design

Optimal efficiency of components built into design; not just "assembled" components

VFD control system

Optimizes plant efficiency though all load conditions; allows for Low Load and Continuous Economizer features

Low Load Controller

Reduces cycling of compressor; allows for continuous operation down to 3% of load

Continuous Economizer Loop

Automatically reduces load by any available "free cooling" tons until it can handle the entire load and shuts down the chiller

Compact footprint

Saves construction costs; allows for easy retrofit application

Mounted cooling tower

Reduces footprint and comes pre-wired and piped to minimize installation costs

Integrated controls

Maximum efficiency and integration of design components; easy interface with BAS

Refrigerant detection and ventilation system

Safety protection and alarm system meets all code requirements

I beams for compressor removal

Ease of maintenance in the event a compressor needs to be removed

Interior service lights and outlets

Convenience lighting and outlets available when inside the unit

ETL labeled and U.L. listed

Piece of mind and added safety; streamlines the installation and inspection process

Single point electrical connection

Reduces installation costs; easy installation to field mounted disconnect switch

Diamond tread plate floor

Prevents slipping if floor gets wet; easy to keep clean

I beam base frame

Structural integrity for crane movement; stable frame for pad or roof curb mounting

Victaulic couplings

Relieves stress of transport allowing some flex in piping; no welds to crack

Fan coil for cooling interior

Maintains equipment and space at a comfortable temperature (<80 degF)

2" double wall acoustical enclosure

Structural integrity; sound attenuation--very quiet operation

Pitched roof design

Keeps water from pooling on the roof

Data Logger

Facilitates troubleshooting in the event of an alarm

Telelink modem

Remote access and programming

Manual-Off-Auto Panel Ability to override any alarms and get unit operating in manual mode
Touch Pilot touch screen Graphical interface for information in unit
   
Optional Features Benefits
Plate & frame heat exchanger Waterside economizing in drier climates; allows Continuous Economizing operation
Primary / Secondary configuration Adds primary pumps to the unit; application specific design; preference of some engineers
Chemical feed station Pre-piped outside the unit; requires mounting and chemical barrels (by others)
Centrifugal water separator Reduces CT maintenance by removing solids from basin
Dolphin Chem-free water treatment Environmental friendly CT maintenance w/o chemicals; guaranteed performance
304S.S. tower sump Reduced scaling and maintenance of CT
Tower fan sound attenuator Reduces tower fan noise
Eye wash station Safety component; installed outside the unit
Compressor removal hoist Used to remove a compressor
Refrigerant alarm Required on most jobs
De-mounted cooling tower Separate CT frame; allows for easy tower installation; typical option for units larger than 300 tons
Extended service warranties  
Comfort View Software Graphically monitor system components
CCN Web interface Internet access to view and/or modify set points (password security levels)
BAS interface (BACnet, LonWorks, ModBus) Easy interface with any BAS; all control points easily provided via interface card
OSHA approved breathing apparatus  
Insulated floor For cold weather climates
Interior piping insulation Reduces mechanical labor in the field